Sale!
In Stock

OPTOS California fa Retina Imaging

Original price was: $10,000.00.Current price is: $6,950.00.

optomap imaging enables detailed examination with no face-to-face interaction
optomap ultra-widefield (UWF) imaging enable eye care providers to see and document the retina with no face-to-face interaction.
Optos UWF technology may help protect patients and staff by reducing the spread of airborne disease.

Brand:Nikon

Description

OPTOS California fa Retina Imaging

California was designed for medical imaging and is available in three models with multiple imaging modality options. California produces a 200°, single-capture retinal image of unrivaled clarity in less than ½ second and is changing management of diseases including DR, AMD, and uveitis.

With California, OPTOS has incorporated new hardware and software technology enabling practitioners to see more, discover more and effectively treat more ocular pathology thus promoting patient health.

In addition to the benefits found with all of the UWF devices from Optos such as 200 degrees or up to 82% of the retina captured in a single image, in multiple modalities, as well as eyecare professionals being able to see 50% more of the retina when compared to other conventional imaging devices, California fa, offers the following benefits:

– Motorized head and chin rest to more easily assist those patients requiring additional assistance during imaging

– Multiple imaging modalities including; 3-in-1 color depth imaging (color, red-free and choroidal in a single image) as well as
autofluorescence and fluorescein angiography

OPTOS California fa Retina Imaging Technical Specifications

Image Views

– Standard:  200⁰ Single Capture
– Auto-montage:  Up to 220⁰ (not available for FA)
– Central Pole:  Detailed view of the macula
–Stereo : Image pairing for optic disc and retinal evaluation

Image Modalities

optomap color and optomap plus (red and green laser):

Color composite view
Green laser view
Red laser view

optomap af (green laser): autofluorescence

optomap fa (blue laser): fluorescein angiography

Resolution

optomap color: 20 μm
optomap plus, af, fa: 14 μm

Wavelengths

Red laser: 635 nm

Green laser: 532 nm

Blue laser: 488 nm

Exposure Time

Less than 0.4 seconds

Footprint

Width: 550 mm / 22 inches
Depth: 550 mm / 22 inches including chinrest
Height: 608-632 mm / 24-25 inches

Weight

34 kg/ 75 lbs

Laser Class

Laser safety Class-1 following IEC/EN60825-1:2007
and 21 CFR1040.10 and 1040.11

System Voltage

US: 100-120V at 50/60Hz
EU/AU: 200-240V at 50-60Hz

Power Consumption

Max. 300 VA

Communication Protocol

DICOM Compatible